Home > Post Error > Post Error 1787-drive Array Operation In Interim Recovery Mode

Post Error 1787-drive Array Operation In Interim Recovery Mode

I was wondering if it is only an option at that point in time on array creation. Refer to the following message. 1786-Slot 1 Drive Array Recovery Needed. Be sure all cables are connected properly and securely. If the replacement drive failed, replace with another drive. his comment is here

Results below: Array: A Interface Type: Parallel SCSI Unused Space: 0MB Status: Failed Physical Drive One of the drives on this array have failed or has been removed. Please find the answers to your queries above. troubleshooting flowchartspage 17................................................................................................................................................................ I did remove the drive marked as failed and replaced it with one of the unassigned drives but this didnt appear to make any difference at all based according to the https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/Drive-array-Device-failure/td-p/3311650

Join them; it only takes a minute: Sign up Here's how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the Press the F2 key to use the drives as configured and lose all the data on them. VirtualizationAdmin.com The essential Virtualization resource site for administrators.

Replace drive X. (depending on the fault-tolerance level, all data may be lost if another drive fails). Select F1 to continue – drive array will remain disabled. How do I replace and (&&) in a for loop? We do not always receive the 1789 alert indicating a failed drive which is weird.

Their last firmware updates occurred in 2008. –ewwhite Jan 6 '13 at 22:34 @user151520 I imported your data into the question. –sysadmin1138♦ Jan 8 '13 at 1:50 Replace drive X. (depending on the fault-tolerance level, all data may be lost if another drive fails). 3. 1788-Slot X Drive Array Reports Incorrect Drive Replacement... ...The following SCSI drive(s) should Should I use "teamo" or "skipo"? http://systemmanager.ru/c00724721.en/10969.htm Articles Authors Blogs Books Forefront TMG/UAG Articles Links Message Boards Newsletter Security Tests Services Software WhitePapers About Us : : Product Submission Form : Advertising Information WindowsSecurity.com is in no way

Action: • Perform one of the suggested actions: • Press the F1 key to retry Automatic Data Recovery to the drive. Mine just reported "Rebuild" as the state. more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed By using our site, you agree to our use of cookies.

This message is displayed if the F2 key was pressed during a previous boot or if the F1 key was pressed during a previous boot and the system rebooted before the https://www.manualslib.com/manual/72576/Hp-Hp-Prolight-Server.html?page=121 The failed drive will not be rebuilt and the system will continue to operate in a failed state of Interim Data Recovery Mode. Through power, I gain victory. Powered by phpBB SysAdmin's Diary Through passion, I gain strength.

Home | My Manuals | Manual Index | Manual Categories | About Us | Contact Us | Privacy HP ProLiant サーバー - エラー番号17xxのPOSTエラー (ハードウェアの取付、ケーブル接続の確認が必要なもの) についてDocument ID:   n/aCreated:   n/aUpdated:   http://bsdupdates.com/post-error/post-error-1784-drive-array-drive-failure.php The following disk drive(s) need Automatic Data Recovery (Rebuild): Port 1I: Box 1: Bay 1Select "F1" to retry Automatic Data RecoverySelect "F2" to continued without starting Automatic Data Recovery (RESUME = If the disk fails again, exchange it!greetings,Michaelps. You need to replace it with a new one.

o • Replace the failed drive and press the F1 key to rebuild the array. But all you need to do is mark one of the unused drives as a spare to the array, the controller will seize the new spare for the array and start Test and replace defective cables. 2. weblink I do not reply to forumers who 1) consistently don't assign points, 2) ask for step-by-step instructions for a topic but appear to have no IT experience and make no effort

What is the server doing right now? and after some minutes the disk LEDhave a fix led in orange ! You can post a comment or trackback from your blog. { 2 } Comments 9m2pju | November 6, 2011 at 3:59 am | Permalink Using Google Chrome 15.0.874.106 on Windows 7

There's a high-likelihood that this is the result of read errors on the remaining drives in the RAID 5 array. –ewwhite Jan 6 '13 at 21:46 add a comment| Your Answer

Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking What controller? 0 Kudos Reply SAKET_5 Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎06-22-2004 01:03 AM Long story..Upgrading the FW could possibly help but due to the nature and importance of these servers, toasting another OS is too risky. Solved!

Action: • Perform one of the following actions: o Press the F1 key to continue with recovery of data to the drive. The operating System is Windows 2008 R2 and is still functional (its serving its purpose). Magalhaes Thomas Shinder Brien Posey Deb Shinder Justin Troutman Mitch Tulloch Robert J. check over here Press the F2 key to continue without recovery of data to the drive.

MSPAnswers.com Resource site for Managed Service Providers.