Home > Post Error > Post Error 1787-drive Array Operating In Interim Recovery Mode

Post Error 1787-drive Array Operating In Interim Recovery Mode

What controller? 0 Kudos Reply SAKET_5 Honored Contributor [Founder] Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎06-22-2004 01:03 AM Heidelberg Martin Kiaer Ricky M. Following a system restart, this message notes that drive X is defective and fault tolerance is being used. Don't show me this message again. his comment is here

For more information, see "Resolving loose connections" in the HPE ProLiant Gen9 Troubleshooting Guide, Volume I on the Hewlett Packard Enterprise website. Audible Beeps: None Possible Cause: System is in Interim Data Recovery Mode and a failed or replacement drive has not yet been rebuilt. Select F1 to continue – drive array will remain disabled. A cable has failed. https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/Drive-array-Device-failure/td-p/3311650

How to improve this plot? Replace drive X. (depending on the fault-tolerance level, all data may be lost if another drive fails). Otherwise it showed the same info as previous (still 2 unassigned drives) –user151520 Jan 6 '13 at 20:05 add a comment| up vote 0 down vote The unassigned drive has controller

The Following SCSI Drive(s) Should Be Replaced: SCSI Port Y: SCSI ID Z ビープ音 なし 考えられる原因 ドライブまたはSCSIケーブルの障害が検出されました。 対処方法 すべてのケーブルが正しくしかもしっかりと接続されていることを確認します。 すべてのドライブが確実に固定されていることを確認します。 障害のあるケーブル、ドライブX、またはその両方を交換します。 1787-Drive Array Operating in Interim Recovery Mode... ビープ音 なし 考えられる原因 What Our Users Say Press & Media Contacts Advertising DMCA Policy Brands × Login Login to ManualsLib Don't have an account? Skip to content HomeAboutDisclosurePolicy { 2011 11 02 } Linux On HP ProLiant: Verifying Hard Disk & Smart Array Problem From OS Level Prologue My friend who is from other team Introductionpage 10................................................................................................................................................................

If the rebuild was aborted due to a read error from another physical drive in the array, back up all readable data on the array, run ADU, and then restore the F2キーを押して、応答しないドライブを無効にします。 b. 故障したドライブを交換します。 F1キーを押してコントローラ上のすべての論理ドライブを無効にした状態でシステムを起動します。 システムの電源投入および切断は、必ず、正しい手順で行ってください。 • システムに電源を投入する際は、すべての外付ストレージ システムの電源を入れてからサーバの電源を入れ なければなりません。 • システムの電源を切断する際は、サーバの電源を切ってから、外付ストレージ システムの電源を切るように しなければなりません。 関連情報 » HP ProLiantサーバ トラブルシューティング ガイド » HP ProLiant サーバー - アレイコンフィギュレーションユーティリティ (ACU) からアレイ診断ユーティリティ (ADU) レポートを取得する方法 » HP This message is displayed if the F2 key was pressed during a previous boot or if the F1 key was pressed during a previous boot and the system rebooted before the The two remaining drives show up as unassigned in the Array Configuration Utility.

Automatic Data Recovery Previously Aborted!... ...The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z Select F1 to retry Automatic Data Recovery to drive. When the drives were swapped, the server showed question marks for the drive that was replaced. Show all Bl35p Bl40p Bl460c Bl480c Bl680c g5 Dl560 Dl590/64 Dl740 Ml310 Ml330 Ml570 Comments to this Manuals Your Name Enter your comment: Symbols: 0 Enter text from picture: Write a I admit I should have ideally set the hot spares when the array was created - am now learning the hard way.

You need to replace it with a new one. https://www.manualslib.com/manual/72576/Hp-Hp-Prolight-Server.html?page=121 Don't show me this message again. Why don't browser DNS caches mitigate DDOS attacks on DNS providers? I don't remember exactly how can this be done from the configuration utilities, but I'm quite sure that you can find out from the Controller BIOS upon rebooting a machine, or

A bad power cable connection to the drive, noise on the data cable, or defective SCSI cable exists. this content If the drive rebuild is not successful or is aborted because the system rebooted before the rebuild of the drive completed, another version of the 1786 POST error message will be Action: Be sure all cables are connected properly and securely. The following SCSI drive(s) were incorrectly replaced: SCSI Port y: SCSI ID z.

I was wondering if it is only an option at that point in time on array creation. Browse other questions tagged hp hp-proliant hardware-raid raid5 hp-smart-array or ask your own question. Be sure all drives are fully seated. weblink If the disk fails again, exchange it!greetings,Michaelps.

Restore password × Upload manual upload from disk upload from url Thank you for your help! To print the manual completely, please, download it. Sign In Upload Page of 139 Go Download Table of ContentsContents TroubleshootingTroublesh..

does the disk management in the Proliant utilities see the new drive?

Audible Beeps: None Possible Cause: Replacement drives may have been installed in the wrong drive bays. Sign up! Hide thumbs 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 What Our Users Say Press & Media Contacts Advertising DMCA Policy Brands × Login Login to ManualsLib Don't have an account?

Through strength, I gain power. Then, replace the defective cables, drive, or both. Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking check over here troubleshooting flowchartspage 17................................................................................................................................................................

The drives are of insufficient size. Test and replace defective cables. 2. HPACUCLI> ctrl all show config detail Based on that, we'll be able to determine if the array is in the dreaded "Waiting for Rebuild" state. Data will be automatically restored to drive X when a failed drive has been replaced, or to the original drive if it is working again without errors.

Chassis Slot: 1 Hardware Revision: Rev B Firmware Version: 2.32 Rebuild Priority: Low Expand Priority: Low Surface Scan Delay: 15 sec Cache Board Present: True Cache Status: Disabled Accelerator Ratio: 50/50 Filed under HP Proliant, Linux, RHEL. In order to use it you have to set it as a global hot spare (or dedicated HS for the VD). troubleshooting guidepage 1................................................................................................................................................................

Interviewee offered code samples from current employer -- should I accept? Test and replace defective cables. I have a new guy joining the group. Join them; it only takes a minute: Sign up Here's how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the

What to do with my pre-teen daughter who has been out of control since a severe accident? HP websitepage 69................................................................................................................................................................ Another thing to ask: Which exact model raid controller and what version on the drivers, the raid firmware and the ACU utilities ? Got it, continue to print 2012-2016 ManualsLib.com About Us About ManualsLib Privacy Policy F.A.Q.

They are now just showing up as 2 unassigned drives. For sanity sake I do recommend moving the drive to a physical arrangement that "matches" the logical grouping. share|improve this answer answered Jan 6 '13 at 19:49 ewwhite 152k47301578 Thanks I will give this a go and post my results once I get them tomorrow. –user151520 Jan Print This PagePrint ShareShare Url of this page: HTML Link: Bookmark Manuals Brands HP Manuals Server ProLiant ML370 Generation 6 Reference and troubleshooting manual HP ProLiant ML370 Generation 4 Reference And

To print the manual completely, please, download it.