Home > Post Error > Post Error 1786

Post Error 1786

Bay 8 blinking green. The server has not been rebooted until now. Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking I'm not a PC guru by any stretch, but this was a godsend. his comment is here

Subscribing... Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small Not sure if there's a pedestal one.   0 Pimiento OP justinh2 Jul 31, 2014 at 11:25 UTC Yes that's the version they have, it's rack-mounted. Ever have a signature collision problem (especially with Virtual Machines?) This article is intended to help you understand what's going on and… Storage Storage Hardware MS Legacy OS Virtualization Dell Equalogic https://community.hpe.com/t5/ProLiant-Servers-ML-DL-SL/POST-Error-1786-Drive-Array-Recovery-Needed/td-p/4540443

But let me absorb wht you have written. 0 Message Author Comment by:afflik19232011-04-11 I'm not to sure I fully understand "I would quiesce the OS (like Windows shutdown but not Logical volume 2 consists of 4 drives in RAID 5 in bays 1-4. This is the boot volume for Windows.

Krzesinski (herton) wrote on 2013-01-15: #13 I meant to say *comment #9*, not commit :) Nick Moffitt (nick-moffitt) wrote on 2013-01-22: #14 We upgraded to 3.2.0-36-generic at your recommendation and added Therefore the green disk light whish is on the other drives. Never turn off a server when you are in a degraded array state.  The drives should be replaced while the system is alive.  Rebooting is one of the most dangerous operations What's probably happened is one of the disks went offline (could have been weeks ago) and then when rebooted both disks are seen again but the controller knows one of them

I'm a little confused now as to whether or array is still intact or recoverable in some way, or if something has happened and the entire array is lost. but the hp controllers are well engineered to deal with this. Causes of the error: Windows Windows Post Error: 1786-drive Array Recovery Needed are caused by misconfigured system files. ty ty ty Megan Says: at 9:12 AM it worked!!!!!!!

Will it not pickup that it now has a good drive but empty and then resync it? Get Your PC Running Normal Again in Under 10 Minutes Filed in Windows Windows Post Error: 1786-drive Array Recovery Needed on Problem with Windows Post Error: 1786-drive Array Recovery Needed? They are sourcing a replacement drive (and an additional hot-swap spare) ASAP. Report a bug This report contains Public information Edit Everyone can see this information.

All drives are ok with solid green. http://systemmanager.ru/c00724721.en/11636.htm Thanks for green tick info. 0 Message Author Comment by:afflik19232011-04-11 Okay, upon further investigation the situation is as follows: OS: Windows Server 2003 Server: Thanks for the help everyone. 1 Habanero OP AceOfSpades Jul 31, 2014 at 10:26 UTC Get the new drive and battery ASAP, don't delay this.  Replacing the drive By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner

We are under staffed tomorrow. this content My worry exactly, no redundancy! Take a full backup NOW. 0 LVL 55 Overall: Level 55 Server Hardware 42 Storage 39 Message Active today Assisted Solution by:andyalder2011-04-06 Can you post the ADU repoort **As attachment, Will let you kow how the rebuild and eventual checkdsk work out.

How do I check without rebooting the server if the raid is okay, HP Drive Array Utility does not open but the log file does. Join the community of 500,000 technology professionals and ask your questions. Audible Beeps: None Possible Cause: System is in Interim Data Recovery Mode and a failed or replacement drive has not yet been rebuilt. weblink To Fix the problem you need to follow the 3 steps : STEP 1: Download & Install RegCure Pro for Free.

Thanks 0 Write Comment First Name Please enter a first name Last Name Please enter a last name Email We will never share this with anyone. Herton R. Rebuild should be automatic.

if your battery is dead or NVRAM doesn't match metadata, and lun has to figure out it is degraded, then you risk losing the config if you have a hiccup.

There was a commit that went later on Precise 3.2.0-34.53 kernel (commit 21e89afd325849eb38adccf382df16cc895911f9, [SCSI] hpsa: Use LUN reset instead of target reset), that may relate to the problem listed on HP's By downloading and running the registry repair tool RegCure Pro, you can quickly and effectively fix this problem and prevent others from occuring. in perfect world it would not matter. To view this page ensure that Adobe Flash Player version 10 or greater is installed.

Any suggestions or pointers always appreciated Thanks 0 LVL 55 Overall: Level 55 Server Hardware 42 Storage 39 Message Active today Assisted Solution by:andyalder2011-04-11 Replacing a faulty disk it will Joseph Salisbury (jsalisbury) wrote on 2013-01-11: #6 You can do it this way: apport-bug --save /tmp/report.1098262 linux Then attach the file report.1098262 to the bug. As far as I know that is what was done 3 months ago, the drive was replaced with a new one, although larger (size is not a problem it will just check over here Action: Perform one of the following actions: Press the F1 key to continue with recovery of data to the drive.

Join Now For immediate help use Live now! o • Replace the failed drive and press the F1 key to rebuild the array. From a terminal window please run: apport-collect 1098262 and then change the status of the bug to 'Confirmed'. Drive in bay 7 showed steady amber light, indicating some sort of problem.

The root issue we had not addressed was that an earlier hard drive repalcment had actually compelted. I have several users working on this server at the moment. Comment Submit Your Comment By clicking you are agreeing to Experts Exchange's Terms of Use. Obviousy I'm tempted to unplug thedrive that the software says has failed, but I don't want to spent the night rebuilding a server when we are under staffed tomorrow. 0

Plug in the external drive you wish to encrypt: Make sure all previous data on the drive has been … Storage Windows Server 2012 – Configuring as an iSCSI Target Video Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking Join & Ask a Question Need Help in Real-Time?