Home > Post Error > Post Error 1784 Drive Array Failure

Post Error 1784 Drive Array Failure

I talked to a recovery specialist years ago. How to fix it depends on the type of array you are using. HomeChange ViewPrint 1784-Slot X Drive Array Drive Failure. Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL http://bsdupdates.com/post-error/post-error-1784-drive-array-drive-failure.php

We have written the day off business wise so another few hours will not do much harm I suppose!   0 Mace OP Huw3481 Nov 4, 2013 at You may have to register before you can post: click the register link above to proceed. Equally thanks to Spiceworks and the community have made a new contact in Huw who works close to where I am based. And have you actually swapped the disks or have HP not sent one yet? 0 Anaheim OP Craig G UK Nov 4, 2013 at 3:15 UTC Huw, What

The Controller (P410) is workling fine and one of the drives is showing a steady amber light. Let me cogitate for a moment. 0 Mace OP Huw3481 Nov 4, 2013 at 1:55 UTC HD IT Solutions is an IT service provider. It won't work. Home Proliant ML330 G6 - RAID / logical drive failure by Craig G UK on Nov 4, 2013 at 1:44 UTC | HP Hardware 0Spice Down Next: HP 377DW - Can

To find the number of X completed, when can I subtract two numbers and when do I have to count? Your faith in the product and the support team is much appreciated.  Lucky, lucky you....to be so near to the remarkable expert Huw.  As you are aware, his knowledge if HP If this message is displayed after Options ROMPaq is run, problems may have occurred while attempting to flash the ROM. At this point it goes no further.Apon more investivation in the iLO the following errors are reported: POST Error: 1784-Drive Array Drive FailurePOST Error: 1789-Drive Not Responding, Physical DriveI've tried removing

Your data was striped across disks, and the failure of one renders the logical drive unusable. So, every cloud maybe after all does have a silver lining. :)           0 Datil OP [email protected] Nov 5, 2013 at 4:29 UTC Brand The disk only shippied today - so it will be here tomorrow. which is how I found it this morning.   The guy from HP said that these problems did not happen very often, maybe twice per year.

When powering down the system, the server must be powered down before powering down any external storage systems. 1783-Slot X Drive Array Controller Failure Audible Beeps: None Possible Cause: Controller failed. x x) has a type, then is the type system inconsistent? If you are unable to run scandisk, you may need to replace the hard drive. I thought it odd, but could not understand why HP Support would not go through this routine with me - hence my reluctance to press F2...

If the problem persists, replace the array controller. 3. 1783-Intelligent Drive Array Controller Failure Audible Beeps: None Possible Cause: Integrated array controller firmware is corrupt, or the controller failed. http://serverfault.com/questions/661255/recovering-data-from-a-failed-sas-drive-raid0-yes-i-know Please try the following:Use a different search stringIf search was based on document ID, check document ID or switch to keyword search Change your search criteria selectionCheck your search string for I still have faith in the product, am desperately pleased we have support in place with yourselves until 2015 and am quite happy to put this down to experience. I was not able to re-enable the Raid array and the last thing that HP could recommend over the phone was to send out a replacement drive.

Good luck and let us know what the outcome is! this content Don't let them spin anymore. Just let it continue booting with drive disabled. By using our site, you agree to our use of cookies.

All drives are blinking green. Join them; it only takes a minute: Sign up Here's how it works: Anybody can ask a question Anybody can answer The best answers are voted up and rise to the Please allow me to clarify this was not a rant about about the product or the support I received. weblink Action: Reboot the server.

The array may just auto-rebuild itself. Join Now Hi all, Came into work this morning to find my HP ML330 (main server running as file server and CRM for the business) was stuck in a boot cycle Personally, I would contact Compaq tech support for assistance.

Server has come back up and I am now getting all the data copied and backed up (in triplicate).

Hang on, you're getting a 1769 error on POST?   0 Mace OP Huw3481 Nov 4, 2013 at 3:28 UTC HD IT Solutions is an IT service provider. I'm wondering, what are the chances of any data recovery at this stage? how can i fix it.Bests regardsM 0 Kudos Reply All Forum Topics Previous Topic Next Topic 3 REPLIES Don Billing_1 Occasional Visitor Options Mark as New Bookmark Subscribe Subscribe to RSS Once the array has been rebuilt you should be cooking on gas.   Edited Nov 4, 2013 at 4:15 UTC 0 Datil OP [email protected] Nov 4, 2013 at

more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed If the SAS-HDD has an Head-Crash for example and you try to power it up again and again the damage may only get more worse... Not cheap, but equally our data is valuable to us. http://bsdupdates.com/post-error/post-error-1797-drive-array-array-accelerator-read-error-occurred.php What does this error exactly mean and what would you suggest as a next step?

Phoned HP support and spent an hour going through various tests etc using the SmartStart CD. Print This PagePrint ShareShare Url of this page: HTML Link: Bookmark Manuals Brands HP Manuals Printer ProLight Server Troubleshooting manual HP ProLight Server Troubleshooting Manual Page 119 Hewlett-packard proliant servers troubleshooting Reply With Quote Quick Navigation Desktop Computer Hardware Top Site Areas Settings Private Messages Subscriptions Who's Online Search Forums Forums Home Forums Center For Disease Control Security News / Warnings / By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner

What does it think it has in there? 0 Anaheim OP Craig G UK Nov 4, 2013 at 2:07 UTC Hi Huw, Can't say I saw that -