Home > Post Error > Post Error 1784-drive Array Drive Failure

Post Error 1784-drive Array Drive Failure

Home Proliant ML330 G6 - RAID / logical drive failure by Craig G UK on Nov 4, 2013 at 1:44 UTC | HP Hardware 0Spice Down Next: EliteDesk Came with a Do you get the F8 prompt on boot to go into the array config? Email Reset Password Cancel Need to recover your Spiceworks IT Desktop password? The array may just auto-rebuild itself. his comment is here

asked 1 year ago viewed 1678 times active 1 year ago Related 3Recovering data from SAS drives after failed SAS Controller Card?5Identify HP Array Logical Drive From Windows0HP B110i controller not Replace defective cables, drive X, or both. I have a SATA-to-USB adapter, I know the physical adapter is the same for SAS, but I'm guessing this won't actually work for connecting to a SAS drive. Any ideas?7HP SmartArray P400: How to repair failed logical drive?1HP P410i Array Controller and lost logical Drive3HP DL380 G5 Predictive failure of a new drive1How to replace failed drive in RAID https://community.hpe.com/t5/Disk-Arrays/POST-Error-1784-Drive-Array-Drive-Failure/td-p/3525905

C:\Documents and Settings\Administrator>RegCure Pro.exe Windows Windows Post Error: 1784-drive Array Drive Failure may caused by some of the following errors Windows Explorer ErrorsJavascript ErrorsHardware MalfunctionError Symptom include:Can not printing fileBlue ScreenIO You may have a mechanical problem with the disk. Amber drive is obviously the one showing a failure. 0 Mace OP Huw3481 Nov 4, 2013 at 3:13 UTC HD IT Solutions is an IT service provider.

Hang on, you're getting a 1769 error on POST?   0 Mace OP Huw3481 Nov 4, 2013 at 3:28 UTC HD IT Solutions is an IT service provider. If everyone. critical failure). Seems odd.  Even if one drive is gone, the array should still be working.

does it still think you have one Logical drive made up of 4 drives in a 1+0? 0 Anaheim OP Craig G UK Nov 4, 2013 at 2:27 By creating an account, you're agreeing to our Terms of Use and our Privacy Policy Not a member? Regcure found over 2500 errors including the Windows Post Error: 1784-drive Array Drive Failure and fixed them all. https://community.hpe.com/t5/Disk-Arrays/post-error-1784-Drive-array-drive-failure/td-p/3710783 Text Quote Post |Replace Attachment Add link Text to display: Where should this link go?

Phoned HP support and spent an hour going through various tests etc using the SmartStart CD. So I have been looking at data recovery solutions. Add Cancel × Insert code Language Apache AppleScript Awk BASH Batchfile C C++ C# CSS ERB HTML Java JavaScript Lua ObjectiveC PHP Perl Text Powershell Python R Ruby Sass Scala SQL There are also various "\device\harddisk3\dr3 has a bad block" errors within the eventlog.

RegCure worked like a charm on the first try. http://serverfault.com/questions/661255/recovering-data-from-a-failed-sas-drive-raid0-yes-i-know Does the code terminate? i.e. Restore data from backup if replacement drive(s) have been installed " Your server is never going to restart unless you press F2, as there is no logical drive for the server

ty ty ty Louann Says: at 9:12 AM it worked!!!!!!! this content In the HP iLO console, we see: POST Error: 1784-Drive Array Drive Failure On the front indicator panel of the drive, there is a steady amber light (i.e. STEP 2:Click the "Quick Scan" button. HomeChange ViewPrint 1784-Slot X Drive Array Drive Failure.

Plus the HP guy never even mentioned this line of repair, so it makes me a bit twitchy. It won't work. What you. http://bsdupdates.com/post-error/post-error-1784-drive-array-failure.php He told me one of the big failures costumers make is that they try to much on their own.

Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking no more errors and officially back in action. Got it, continue to print 2012-2016 ManualsLib.com About Us About ManualsLib Privacy Policy F.A.Q.

Is the controller replacable?

It's possible that the SMART technology in one of the drives is reporting an imminent failure even though it is working for the time being.Don 0 Kudos Reply The opinions expressed And you're not getting a 1784 or 1786 error on POST? possibly 9 years... All rights reserved.

Thank you!   Reply Subscribe View Best Answer RELATED TOPICS: RAID 5 failure on logical drive- what to do? Last solution is to replace the motherboard. what's wrong now?Best regardsM 0 Kudos Reply Don Billing Occasional Visitor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎04-19-2005 http://bsdupdates.com/post-error/post-error-1797-drive-array-array-accelerator-read-error-occurred.php Server is functioning in Interim Recovery Mode and advises the replacement of the failed hard drive (which I assume I can do upon receiipt of new hard driver tomorrow).   I