Again, sincere thanks. 0 Mace OP Huw3481 Nov 4, 2013 at 4:02 UTC HD IT Solutions is an IT service provider. Any one know of any good reliable data recovery companies in the UK, preferably East Midlands / South Yorkshire etc? It says that disk 2 is faulty.   A chap from Data Recovery suggested that depsite other 3 drives showing OK, chances are we have got multiple drive failures - hence your firmware is VERY old. 3.0 came out in March 2010 and the latest version is 6.40 so you should really consider looking at updating firmware on the controller, the system his comment is here

If drives have not been replaced, this message indicates an intermittent drive failure. Skip to ContentSkip to FooterSolutions Transform to a Hybrid Infrastructure Protect Your Digital Enterprise Empower the Data-Driven Organization Enable Workplace Productivity Cloud Security Big Data Mobility Infrastructure Internet of Things Small You need to at least learn the basic procedures of your PC in order for you to troubleshoot Post Error 1779-drive Array Controller Detects Replacement Drives. Not a member? check these guys out

So, every cloud maybe after all does have a silver lining. :)           0 Datil OP [email protected] Nov 5, 2013 at 4:29 UTC Brand These products are now supported by HP Inc. The backup is showing as being successful but I am nervous to say the least.

Let me cogitate for a moment. 0 Mace OP Huw3481 Nov 4, 2013 at 1:55 UTC HD IT Solutions is an IT service provider. BSoD Software and hardware updates are necessary to make computer more functional, thus we always want to install such. Thank you! which is how I found it this morning.   The guy from HP said that these problems did not happen very often, maybe twice per year.

It shouldn't do that on a RAID 5. And have you actually swapped the disks or have HP not sent one yet? 0 Anaheim OP Craig G UK Nov 4, 2013 at 3:15 UTC Huw, What When powering down the system, the server must be powered down before powering down any external storage systems. http://h20565.www2.hpe.com/hpsc/doc/public/display?sp4ts.oid=502439&docId=emr_na-c01702138&docLocale=en_US You can then proceed to the advanced tab and settings.

Apologies! 0 Mace OP Best Answer Huw3481 Nov 4, 2013 at 3:35 UTC HD IT Solutions is an IT service provider. It does not matter if you've got the latest operating system because no matter what kind of OS you are using, you are still prone to this error. If incase the problem does not fall to existence of some virus, you must take into consideration another solution which is to reinstall system file or software that is not running. Having said that, the wise move would be to try troubleshooting it first yourself.

Please allow me to clarify this was not a rant about about the product or the support I received. check this link right here now Your thoughts? 0 Anaheim OP Craig G UK Nov 4, 2013 at 3:16 UTC Not yet. End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to select your country ArgentinaAustraliaBelgiqueBoliviaBrasilCanadaCanada-françaisČeská republikaChileColombiaDeutschlandEcuadorEspañaFranceIndiaIrelandItaliaMagyarországMéxicoNew ZealandÖsterreichParaguayPerúPolskaPortugalPuerto This is only a sign that there is something to fix.

Having said that, installing of these things might cause an error that causes a flash of blue screen every time you boot up your computer. this content Community ProLiant Servers (ML,DL,SL) CommunityCategoryBoardUsers turn on suggestions Auto-suggest helps you quickly narrow down your search results by suggesting possible matches as Seems odd.  Even if one drive is gone, the array should still be working. It takes more effort than just simple ESC or Ctrl + Alt + Del in order to solve this concern.

What does it think it has in there? 0 Anaheim OP Craig G UK Nov 4, 2013 at 2:07 UTC Hi Huw, Can't say I saw that - Just click the KUDOS! 1 Kudo Reply Jason_Z Occasional Advisor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content ‎08-28-2014 02:19 Email Reset Password Cancel Need to recover your Spiceworks IT Desktop password? weblink Seems strange to see all of them being hot removed.Otherwise I didn't really see any problems with the array.

With all four drives in, what are the respective colours of the drive LEDs? 0 Anaheim OP Craig G UK Nov 4, 2013 at 3:01 UTC Yeah me Very helpful Somewhat helpful Not helpful End of content United StatesHewlett Packard Enterprise International Start of Country Selector content Select Your Country/Region and Language Click or use the tab key to Click on Advanced system settings at the top left of the window.

That failing drive for instance has firmware HPDD but I think the latest for it is HPDJ.The other model of 146GB drive you have has firmware HPDB but the latest is

guess what it didn't come with!? Showing results for  Search instead for  Do you mean  Menu Categories Solutions IT Transformation Internet of Things Topics Big Data Cloud Security Infrastructure Strategy and Technology Products Cloud Integrated Systems Networking About Advertising Privacy Terms Help Sitemap × Join millions of IT pros like you Log in to Spiceworks Reset community password Agree to Terms of Service Connect with Or Sign up not sure why it would give a POST code.Of course, removing and reinserting a drive will sometimes clear up some things, so maybe it "fixed itself". :) 0 Kudos Reply Jason_Z

Equally thanks to Spiceworks and the community have made a new contact in Huw who works close to where I am based. An updated version of antivirus and also malwares will be the best answer for this kind of error. Knowing the primary cause of a specific error is essential in here to be able to implement the right solution. check over here The drives also need some firmware updates.Drive 4 shows the last failure reason as "hot removed" which is probably when you pulled it, so that's to be expected, but drive 3

The guy did his best and was professional throughout, I think on this one occasion he just overlooked something simple - a crime we are all guilty of from time to If you know how to fix Post Error 1779-drive Array Controller Detects Replacement Drives by yourself, you will be saving enough some of money. Please try the following:Use a different search stringIf search was based on document ID, check document ID or switch to keyword search Change your search criteria selectionCheck your search string for Hang on, you're getting a 1769 error on POST?   0 Mace OP Huw3481 Nov 4, 2013 at 3:28 UTC HD IT Solutions is an IT service provider.

Your cache administrator is webmaster. Low Virtual Memory RAM is an important component of your personal computer. This problem actually has a quick alternative fix and it's through boosting your pagefile size. Array A says RAID 1, Array B says RAID 5.Update those firmwares (you'll need to reboot) and then see how things look.

The problem known as low virtual memory results from the prolong usage of such programs or apps that exhaust the RAM space. Once you've got your data off, try booting into normal mode. Server is functioning in Interim Recovery Mode and advises the replacement of the failed hard drive (which I assume I can do upon receiipt of new hard driver tomorrow).   I Your faith in the product and the support team is much appreciated.  Lucky, lucky you....to be so near to the remarkable expert Huw.  As you are aware, his knowledge if HP

Once the array has been rebuilt you should be cooking on gas.   Edited Nov 4, 2013 at 4:15 UTC 0 Datil OP [email protected] Nov 4, 2013 at What you have to know is that Post Error 1779-drive Array Controller Detects Replacement Drives is normal. Like I said, it *shouldn't* cause the array to disappear... So, the user reset the system and saw the following messages: Slot 2 HP Smart Array P812 Controller 1 Logical Drive 1779-Slot 2 Drive Array - Replacement drive(s) detected OR previously