YMMV.       0 Anaheim OP Craig G UK Nov 4, 2013 at 3:40 UTC Yes this is the one. If drives have not been replaced, this message indicates an intermittent drive failure. Let the controller discover the new array. And we were the (un)lucky winners!      0 Mace OP Huw3481 Nov 4, 2013 at 2:57 UTC HD IT Solutions is an IT service provider. his comment is here

I had assumed that the RAID metadata stored on the disks would be sufficient to bring the old RAID array back online, but that doesn't seem to be the case. Subscribe to our monthly newsletter for tech news and trends Membership How it Works Gigs Live Careers Plans and Pricing For Business Become an Expert Resource Center About Us Who We Comment Submit Your Comment By clicking you are agreeing to Experts Exchange's Terms of Use. Can you please list all your POST errors?   0 Anaheim OP Craig G UK Nov 4, 2013 at 3:30 UTC Sorry  - it is the 1779 error

thx again for confirming 0 LVL 7 Overall: Level 7 Storage 1 Message Author Comment by:rpliner2011-09-27 if anyone sees this, please respond. The disk only shippied today - so it will be here tomorrow. Removing the drive did not help and there seemed to be no way to re-enable the array.

I was not able to re-enable the Raid array and the last thing that HP could recommend over the phone was to send out a replacement drive. Please try the following:Use a different search stringIf search was based on document ID, check document ID or switch to keyword search Change your search criteria selectionCheck your search string for Join Now For immediate help use Live now! I've pulled full arrays from 6000 series controllers and used them on 7000 series controllers.

Action: Reboot the server. Privacy Policy Site Map Support Terms of Use By using our site, you agree to our use of cookies. It should stay up. http://h20564.www2.hpe.com/hpsc/doc/public/display?docId=emr_na-c03593917&sp4ts.oid=4231377 Will try back it up though.Cheers 0 Kudos Reply PGTRI Honored Contributor Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate Content

asked 5 years ago viewed 92959 times active 3 months ago Related 2HP ProLiant server - multiple raid controllers?2Smart Array P600: Can't get drives recognized on port 2i4Slow parity initialization of Get 1:1 Help Now Advertise Here Enjoyed your answer? Once enabled, one could see the drives from the OS. The RAID controller is refusing to recognize inserted drives as an array.

I'm not sure if this question should be deleted, since I answered it myself so quickly. By creating an account, you're agreeing to our Terms of Use and our Privacy Policy Not a member? Phoned HP support and spent an hour going through various tests etc using the SmartStart CD. Boot up the server and acknowledge errors about failed drives Insert new drives and create new RAID10 array Format new array and restore data from tape backup.

Is unpaid job possible? this content Your cache administrator is webmaster. Any one know of any good reliable data recovery companies in the UK, preferably East Midlands / South Yorkshire etc? if not, i'll order one. 0 LVL 7 Overall: Level 7 Storage 1 Message Author Comment by:rpliner2011-09-26 will have on tomorrow and will hot swap it.

Plug in the external drive you wish to encrypt: Make sure all previous data on the drive has been … Storage Reformatting Your Flash Drive Video by: Faizan This Micro Tutorial When powering down the system, the server must be powered down before powering down any external storage systems. Try this. weblink Port 85 codes and iLO messagespage 131................................................................................................................................................................

By using this site, you accept the Terms of Use and Rules of Participation. End of content United StatesHewlett Packard Enterprise International CorporateCorporateAccessibilityCareersContact UsCorporate ResponsibilityEventsHewlett Packard LabsInvestor RelationsLeadershipNewsroomSitemapPartnersPartnersFind a PartnerPartner This procedure worked as expected. If the problem still exists and a cache memory module is attached to the controller, replace the cache memory module and reboot the server. 1784-Slot X Drive Array Drive Failure.

It started with 8 x 250GB drives: 2 in RAID1 for the OS 5 in RAID5 for data 1 as a hot spare.

Help Desk » Inventory » Monitor » Community » current community blog chat Server Fault Meta Server Fault your communities Sign up or log in to customize your list. So you're seeing this? "1779 - Slot X Drive Array - Logical drive(s) previously failed... ...Select "F1" to continue with logical drives disabled Select "F2" to accept data loss and to If not, which RAID controllers support this, so I know what to buy in the future? The user saw the following messages: Smart Array P812 in Slot 2 Array A (SAS, Unused Space: 0MB) Logical drive 1 (5.5 TB, RAID 50, Failed) The IML log shows: POST

I can hardly believe that the drives would be rendered inaccessible as soon as they are removed from the original RAID controller. Alternatively does anyone have any suggestions as to things as yet untried to ressurect the dead drive? ADU will help in identifying it. check over here Amber drive is obviously the one showing a failure. 0 Mace OP Huw3481 Nov 4, 2013 at 3:13 UTC HD IT Solutions is an IT service provider.

Action: Update the controller to the latest firmware version 1. Then turn system power OFF and move drives to their original positions. The following process was used: Shut down server Remove drives used in data array and hot spare, and label with their positions. All rights reserved.

I still have faith in the product, am desperately pleased we have support in place with yourselves until 2015 and am quite happy to put this down to experience. The backup is showing as being successful but I am nervous to say the least. All tasks are done in Disk Utility. When the new drive turns up, plug it in and the array will go into recovery.  You should be able to continue to use the server whilst it is recovering, it'll